Private rented buildings over 1,000 m² · England and Wales

EPC B \"where cost effective\": the payback test in the 2031 proposal

Three words in the Government's proposal for large let buildings carry most of the weight for anyone with an expensive building to improve: "where cost effective". This page explains what is known about them, and what you can prepare before the detail is published.

What the proposal says

The interim response of 18 June 2026 says that "from 2031, it is proposed that all private rented buildings over 1,000 square metres in England and Wales will need to reach ... EPC B, where cost effective".

It also says that the 7-year payback test and the existing exemptions are retained.

So the proposal is not "B at any price". It is B where the cost can be justified on the test that already exists, with the same exemption routes as today. Both remain proposals until the Government introduces legislation, which it says it aims to do "at the earliest opportunity".

The test that exists today

Under the current EPC E standard, one of the registered exemptions is the 7-year payback exemption. A measure, or package of measures, fails the test where the expected value of the energy bill savings over seven years from installation is less than the cost of buying and installing it.

To register the exemption today, the Government's guidance asks for three quotes from qualified installers, confirmation that you are satisfied the measures fail the test, and copies of your cost calculations.

An exemption registered on the PRS Exemptions Register lasts 5 years. Giving false or misleading information on the register can lead to a penalty of up to £5,000.

What we do not know yet

The response says the 7-year payback test and the existing exemptions "will remain in place" for the proposed 2031 standard. It gives no further detail on how the test will apply at B rather than E. That has not been published yet, so check again when the regulations appear. Open questions include:

The answers will come with the regulations and updated guidance. Plan around the principle, not around a guess at the detail.

The other exemptions that are retained

The existing exemptions are, in the Government's guidance:

Each is registered, not assumed. Our figures cannot see them: a building we count as below B may already hold an exemption under the current rules.

Building your evidence now

Whatever the final test looks like, it will turn on evidence about your building. You can start assembling it without waiting:

  1. A current certificate. If yours predates 15 June 2022, a new assessment may rate the building differently; see why a new EPC may score higher. Any payback case should start from a rating the regulator will accept.
  2. The recommendations. Assessors' recommendations are lodged in the register alongside non-domestic certificates. Keep yours with the certificate.
  3. Quotes for the measures that would move the rating, in the order an assessor would prioritise them.
  4. Energy bills for the building or the landlord-controlled parts of it, which any savings calculation will need.
  5. Lease terms that affect access or consent, which matter if a third-party consent route is ever needed.
  6. A note of dates. Exemptions last five years; certificates last ten. Line both up against 2031 and your lease events.

None of this commits you to spending. It means that when the regulations arrive, the cost-effectiveness question can be answered from your own figures rather than from scratch.

How your area compares

Your council's page shows how many large let buildings there are rated below B, how much floorspace that is, and how many are on certificates from before June 2022. Find it under councils and regions.

Sources

Checked against primary sources on 2026-10-06. All guides